WORK PERMIT SYSTEM

WORK PERMIT SYSTEM

 Definition: = Meaning
An organized method which authorizes specific activity such as Construction, Maintenance, Inspection or Repair in areas identified by management as restricted and which represent a potential Hazard to company operations, personnel or equipment



(HAZARD means Danger)
AIM OF THE WORK PERMIT SYSTEM
AUTHORIZATION-of Specific Work, in a Specific
Location, inside Restricted Areas
SAFETY – provide a Safe Work Location by identification and elimination of Hazards and lists Minimum Precautions for working Safely
COMMUNICATIONS – awareness
RECORD KEEPING – provides an official record of events and agreements
ACCESS CONTROL – limits personnel in Hazardous Areas
WORK PERMIT SYSTEM BASIC TERMS
RESTRICTED AREAS:
1. AREAS WHERE HYDROCARBONS, FLAMMABLE LIQUIDS, GASES OR OXIDIZING AGENTS, ARE HANDLED, STORED, PIPED OR PROCESSED, IN SIGNIFICANT QUANTITIES.

WITHIN 200 FEET OF POWER LINES.

WITHIN 100 FEET OF PIPELINES.


AREAS OR ACTIVITIES WHICH HAVE BEEN DESIGNATED, BY A DEPARTMENT MANAGER.
WORK PERMIT SYSTEM BASIC TERMS
DESIGNATED REPRESENTATIVE: (CHOSEN) A COMPETENT EMPLOYEE, DESIGNATED (CHOSEN) BY THE ISSUER, WHO IS FAMILIAR
WITH THE REQUIREMENTS OF THE WORK PERMIT SYSTEM AND IS ABLE TO PERFORM ASSOCIATED WORK PERMIT DUTIES. HE DOES NOT SIGN THE WORK PERMIT.
ISOLATION:
A PROCESS WHEREBY THE SYSTEM OR COMPONENT, IS REMOVED FROM SERVICE AND IS COMPLETELY PROTECTED AGAINST THE UNPLANNED ENTRY OF ENERGY, WHETHER IT BE CHEMICAL, MECHANICAL, ELECTRICAL OR PNEUMATIC ENERGY.
REQUIREMENTS OF ISSUING/RECEIVING PERMITS
KNOWING THE SCOPE OF WORK
KNOWING AND UNDERSTANDING THE TYPE(S) OF PERMIT(S) NEEDED
SPECIFIC HAZARD IDENTIFICATION
LOCATION
JOINT SITE INSPECTION
SCOPE means RANGE OF WORK SPECIFIC means (ACCURATE)
HOT WORK ANYTHING THAT CREATES FLAMES, HEAT OR OTHER
IGNITION SOURCES SUCH AS:
HOT TAPPING.
WELDING AND TORCH CUTTING.
VEHICLE ENTRY.
FLASH PHOTOGRAPHY, ABRASIVE GRINDING BLASTING, AND GRINDING.
FIRE TRIANGLE
COLD WORK
WORK THAT DOES NOT CREATE AN IGNITION SOURCE - HEAT, FLAME OR SPARK
BRUSH PAINTING
HAND TOOL WORK
INSPECTION
SCAFFOLD ERECTION
RELEASE PERMIT
POTENTIAL RELEASES OF HAZARDOUS GASES & CHEMICALS SUCH AS:
SWINGING BLINDS
GAS FREEING EQUIPMENT
VENTING TO ATMOSPHERE
OPENING LINES
DEPRESSURIZING HIGH PRESSURE AIR LINES
CONFINED SPACE PERMIT
ENTRY OF PERSONNEL INTO ANY SPACE OR STRUCTURE  NOT NORMALLY INTENDED FOR HUMAN OCCUPANCY, IN  WHICH ENTRY, MOVEMENT OR EXIT IS RESTRICTED




TANKS, TOWERS, VESSELS, EXCAVATIONS 4ft OR DEEPER, SUMPS, SEWERS, VALVE PITS, VESSEL SKIRTS
PEOPLE INVOLVED IN WORK PERMITS
EACH CRAFT MUST HAVE A SEPARATE PERMIT

CERTIFIED ISSUER
ISSUES WORK PERMIT ONLY AFTER:
VISITING THE SITE TOGETHER WITH THE RECEIVER
PERFORMING GAS TEST
LISTING PRECAUTIONS AND RESTRICTIONS
PEOPLE INVOLVED IN WORK PERMITS (CONT.)
CERTIFIED RECEIVER
REQUESTS WORK PERMIT FROM OPS.
ISSUER & RECEIVER ARE RESPONSIBLE FOR:
COMPLYING WITH CONDITIONS AND REQUIREMENTS
KEEPING COPY OF PERMIT IN POSSESSION OR WITHIN VIEW OF THE JOB SITE
STOPPING WORK
CLOSING A WORK PERMIT WITH ISSUER
JOINT SITE INSPECTIONS
DISCUSS SCOPE OF WORK
GAS TESTING
LOCKOUT/HOLD TAGS
SAFETY EQUIPMENT NEEDED
PROCESS HAZARDS
ISOLATION/DEPRESSURIZATION
PHYSICAL HAZARDS
RADIATION HAZARDS
CLOSING A WORK PERMIT
“WORK PERMITS SHALL BE CLOSED BY RECEIVER AND ISSUER EXCEPT WHEN:”
DISTANCE OR REMOTENESS MAKE SIGNING IMPRACTICAL
MUST BE STATED WHEN PERMIT IS ISSUED
PERMIT HAZARDS
FLAMMABILITY/COMBUSTIBILITY
LOWER EXPLOSION LIMIT (LEL) – TOO LEAN
UPPER EXPLOSION LIMIT (UEL) – TOO RICH
FLAMMABLE RANGE – MIXTURE WILL BURN LIMITS:
ANY READING ABOVE 0% LEL- NO HOT WORK PERMITTED.
5% TO 50% LEL- SCOT AIR PAK USED FOR COLD WORK ONLY
ABOVE 50% LEL – NO ENTRY PERMITTED NO WORK PERMITTED
PERMIT HAZARDS (CONT.)
HYDROGEN SULFIDE- TOXICITY
10 PPM, CAN SMELL, PERMISSIBLE FOR 8 HOURS ONLY.
100PPM, KILLS SMELL IN 3-15 MINUTES
500PPM, UNCONSCIOUS IN 15 MINUTES
700PPM, BREATHING STOPS WITHIN MOMENTS
1000PPM, IMMEDIATE UNCONSCIOUSNESS AND DEATH IF NOT RESCUED AND RESUSCITATED
PERMIT HAZARDS (CONT.)
OXYGEN
21% - IS NORMAL
LESS THAN 20%, REQUIRES DIV. HEAD APPROVAL + SAP
ABOVE 23.5% EXTREME FLAMMABILITY HAZARD
EXPOSURE TO LESS THAN 16% CAUSES RAPID UNCONSCIOUSNESS
DURATION OF WORK PERMITS & EXTENSIONS
NORMAL DURATION IS FOR 8 –HOURS  ONLY
CAN BE INCREASED TO 16 – HOURS IF SIGNED BY ISSUER AND RECEIVER COMING ON SHIFT
UP TO 30 DAYS FOR CERTAIN JOBS WITH DIVISION HEAD APPROVAL
GAS TEST LIMITS

H2S )PPM)0 - 10OK TO WORK11 – 100SCOTT AIR PAK> 100SCOTT AIR PAK & SUPT. APPROVALOXYGEN (%)20 – 23.5OK TO WORK<29 & > 23.5SCOTT AIR PAK & SUPT. APPROVALFLAMMABLE GAS (% LEL)0.0

0.5HOT WORK

CONFINED SPACE ENTRY5 – 50COLD WORK WITH SCOTT AIR PAK ISOLATION, LOCKOUT, AND USE OF HOLD TAGS
TYPES OF ENERGY SOURCES EXAMPLES:
ELECTRICAL
FLUID
GASEOUS
MECHANICAL
CHEMICAL
ISOLATION, LOCKOUT, AND USE OF HOLD TAGS
MEANS OF ISOLATION
WHEN THERE IS A POTENTIAL ENERGY, THE SOURCE SHALL BE ISOLATED
BLINDS
CLOSING AND LOCKING OF VALVES
REMOVAL OF PIPING
OPENING AND LOCKING CIRCUIT BREAKERS
DISCONNECT POWER SUPPLIES
ISOLATION, LOCKOUT, AND USE OF HOLD TAGS
∫ PROCEDURES
SPECIFIC ISOLATION, LOCK, HOLD AND TAG PROCEDURES
EACH DEPARTMENT IS RESPONSIBLE FOR IMPLEMENTING LOCKOUT PROCEDURES AND TRAINING
OPERATIONS AND MAINTENANCE SHALL PROVIDE LOCKOUT EQUIPMENT
OPERATIONS SHOULD BE FIRST ON AND LAST OFF LOCK
LOCK, TAG AND TRY
ISOLATION, LOCKOUT, AND USE OF HOLD TAGS
∫ LOCKS
EACH CRAFTSMAN SHOULD HAVE HIS OWN LOCK
ONE LOCK, ONE KEY
TAG MUST HAVE NAME AND PHONE NUMBER AT MINIMUM
FORCED REMOVAL REQUIRES TWO SUPERINTENDENTS. AND DOCUMENTATION
EXCEPTION TO OBTAINING A WORK PERMITS
∫ EMERGENCY ONLY
STILL MUST DO THE JOB SAFELY
COMPLETE PERMITS AS SOON AS POSSIBLE
Prepared by Qaisarhayat daud khel vi
For more update
Visit  htwpk.blogspot.com

Post a Comment

0 Comments